Table of Contents
Electrical maintenance in a commercial building is easy to let slide until a light fails, a socket gets damaged or a circuit starts tripping. A checklist keeps routine checks, inspections and outstanding repairs in one place, so nothing gets missed between visits.
This guide covers what staff can check themselves and what needs an electrician, the core checklist, how often to carry it out, and what to do when it turns up a problem.
The checklist below is a starting point for commercial premises, with extra points for offices, warehouses and factories. It is a planning guide, not a set of instructions for carrying out electrical work.
A useful checklist should cover your electrical records, visible problems, the fixed installation, equipment, lighting and any specialist systems. For each item, record who is responsible, what action is needed and when it should be reviewed.
Staff can note a damaged socket on the checklist. Inspecting the wiring and any testing is the competent electrician’s job, and the two should stay separate. A completed checklist cannot show that the installation is safe. That still needs a competent assessment.
In Great Britain, the Electricity at Work Regulations require electrical systems to be maintained, so far as reasonably practicable, to prevent danger. HSE guidance on the regulations explains the role of inspection and testing. It does not impose one maintenance timetable for every business.
The workplace procedure should tell staff what to report during normal use and who to tell. It should also make clear that technical inspection, electrical testing, isolation and repairs are for competent electricians, not part of staff reporting.
Safe for trained staff to report
Say what was noticed, where and when. Do not try to diagnose it, and do not keep resetting protective devices.
Electrician-only work
Agree on the buildings and areas included, access restrictions and any need for the power to be off before work starts.
Staff role: Observations should be made during normal use, without opening equipment, removing covers or touching anything suspected to be unsafe. Give staff a clear contact and reporting route.
Before booking any work, gather the latest Electrical Installation Condition Report (EICR) together with certificates for alterations, service reports and repair records. An EICR describes the condition of the fixed installation, within the scope agreed for that inspection. It is not ongoing maintenance.
The aim is to give the contractor a useful picture of the premises, not simply a folder full of certificates. Our commercial EICR guide explains inspection scope, timing and records in more detail.
Use the staff visual checks above to explain what needs reporting. Each report should say what was noticed, where and when, without asking staff to diagnose the fault.
Ask a competent electrician to identify the inspection, testing and maintenance your installation needs. This may cover distribution boards, circuits, wiring, protective devices and earthing arrangements, depending on the premises and agreed work.
For planning purposes, check that the quote identifies the buildings and areas included, any access restrictions and any work that will require the power to be off. Do not assume that a brief visual visit includes a full EICR or that repairs are included in an inspection price.
Keep track of the equipment your business uses, including portable appliances and items that are moved, hired or brought into service temporarily. Ask who is responsible for the checks and maintenance each group needs.
HSE electrical equipment guidance says the type and frequency of user checks, inspection and testing depend on the equipment, its environment and previous results. An office computer and a tool used in demanding conditions should not automatically follow the same programme.
Consider new equipment when you review the plan. A label on an appliance does not resolve a newly damaged lead or another fault that develops afterwards.
Record which arrangements cover ordinary lighting, emergency lighting, fire alarms and any other specialist systems on site. These may have their own servicing requirements and contractors.
Ask what is included in your electrical maintenance agreement and what needs a separate appointment. Do not assume that an EICR covers every alarm, emergency system, charger or piece of machinery. Our electrical installation servicing page explains the servicing support available.
The contractor should determine the safe working arrangements, including any isolation needed. Business pressure is not a reason to improvise electrical work or overlook safety.
Use this table as a planning template for your own premises. It is not a certificate of safety. The first row is an example only.
Planning template: electrical maintenance checklist
| Area or asset | Observation or scheduled task | Responsible person | Competent contractor required | Due or review date | Action or evidence |
|---|---|---|---|---|---|
| Example: socket reported damaged | Staff report a damaged socket. Keep people away from it and follow your site procedures. | Site contact | Yes. A competent electrician investigates. Staff should not isolate or repair it. | Report at once. Note the date it was investigated. | What was seen, where, when, who was told, advice given, work done. |
| Electrical records | Latest EICR, certificates for alterations, service reports, repair records. Were earlier recommendations acted on? | Named person | Ask your electrician what further assessment is needed if records are missing. | Review after significant changes to the premises. | A note of each previous recommendation and what happened to it. |
| Fixed installation | A competent electrician sets the inspection and testing scope. | Named person | Yes. This is their work. | As the existing report says. Look again sooner if the premises change or faults keep coming back. | A quote or report showing the buildings and areas covered, access restrictions and any need for the power to be off. |
| Equipment | Keep a list of equipment, including portable, hired and temporary items. Agree who is responsible for each group. | Named person | Depends on the equipment and its environment. Ask a competent person to set the programme. | Review when new equipment arrives. | The equipment list and a record of the checks carried out. |
| Lighting and other systems | Record who covers ordinary lighting, emergency lighting, fire alarms and any specialist systems. | Site contact | They may have their own servicing contractors. | Check what your maintenance agreement includes. | Which arrangement and contractor covers each system. |
Offices and shops
Tell the electrician if desks, displays or tills have moved or a new kitchen appliance has gone in, and if you keep relying on temporary extension leads. Those changes affect where power is needed, and the electrician can judge whether the arrangement still suits the premises. Add the stockrooms and staff kitchens to the areas to be covered. Shops need a word about access too, because some work may have to wait until you are closed.
Warehouses
Vehicles and loading work can affect electrical equipment near the loading bays. Staff should report visible damage and anything that blocks safe access to equipment. If the racking or storage layout has changed, tell the contractor, and mention charging areas and outdoor equipment as well. Lights set high up may need specialist access. Arrange that work properly and do not ask staff to improvise.
Factories and workshops
Bring the machinery maintenance plan into the conversation. Agree where the building installation ends and a machine’s systems begin. Use HSE machinery maintenance guidance as a prompt for competence, manufacturer information and safe planning. Do not wait for the next convenient shutdown if a defect presents a safety concern.
There is no single interval that suits every item in every commercial building. Ask your electrician to build a schedule around the installation’s condition, use, environment, previous findings and relevant manufacturer guidance.
Staff need a way to report faults between scheduled inspections and servicing visits. The existing report will give the next recommended inspection, but ask for the plan to be reviewed sooner if the premises change or faults keep coming back.
Also check any specific lease, insurance or system requirements with the relevant party. A generic checklist should not override a more specific requirement that applies to your premises.
Decide who will arrange the follow-up for each reported fault. Ask a competent person how urgent it is, and do not set the deadline to suit the budget or a convenient visit.
If something appears unsafe, stop using the affected equipment where you can do so safely, keep people away and seek competent help. Do not approach or handle damaged electrical parts. If there is fire or immediate danger, follow your emergency procedure and call the emergency services as appropriate.
For each reported issue, keep a short record of the location, what was observed, who was informed, the advice received and any completed work. Ask what evidence or further checks are needed before returning equipment to use. That makes it easier to spot repeated problems rather than treating each call-out as an unrelated event.
For the budget side of planned and reactive work, see planned vs reactive electrical maintenance.
Employees can record observations and follow checks for which they have suitable instruction and competence. That does not authorise internal inspection, electrical testing or repairs. Make the boundary clear in your workplace procedure.
No. A checklist helps organise maintenance and follow-up. An EICR is a report from inspection and testing of the fixed installation within an agreed scope. Neither should be treated as covering every system or future fault.
No universal annual testing rule applies to every appliance. The appropriate approach depends on the equipment and circumstances. Ask a competent person to set a suitable programme rather than relying on a blanket annual rule.
Yes, as a template. Keep a separate record for each site showing its equipment, who is responsible, the findings and the schedule. A warehouse will need different details from an office, even where both belong to the same business.
List what is missing and give the available reports, repair history and changes to a competent electrician. They can advise what assessment is needed. Do not create retrospective test results or assume an installation is safe because no fault has been recorded.
Related reading
Calder Electrical has been providing electrical services to residential, commercial and industrial properties for over 40 years, and we are specialists in all aspects of electrical installations, maintenance and inspection and testing.
All our work is fully insured, and we work to the standards set by the NICEIC. Our team provides electrical maintenance, installation servicing and a call-out service for unplanned issues.
Arrange a servicing review
Use this checklist to describe your premises, equipment and any unresolved issues when you arrange a review of your electrical servicing needs.
Or would like us to provide a survey and quote then please contact us and we will be happy to help.
Call us on 0800 612 3001